HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Message Type
Description Action
54 REDUNDANCY
FAILED CACHE DIMMS
MISMATCH
Error
The cache memory modules on
the two controllers are not the
same size. All cache memory
modules must be the same size for
redundancy to operate.
Remove the array controller that
has been halted, replace the cache
modules with the appropriately
sized ones, wait 10 seconds, and
then reinsert the array controller,
ensuring that it is fully seated in
the chassis.
57 REMOVE OT
HER
CONTROLLER
NOW
In dual-cont
roller congurations,
the rmware has determined that
the other controller has been
disabled and can safely be
removed.
Remove the ot
her array controller
for the plan
ned service. When
complete, r
einsert the array
controller
, ensuring that it is fully
seated in t
he chassis.
60 NO CACHE MODULE
FOUND
Error
The array controller requires at
least one cache module in order
to operate. Either there is not one
present or it has failed.
Remove the failed array controller,
either add a cache module or
replace the failed one, wait 10
seconds, and then reinsert it,
ensuring that it is fully seated in
the chassis.
If the issue persists, contact HP
support.
61 DUAL CACHE
MODULE SIZE
MISMATCH
Error
The array controller has two cache
modules attached but they are of
different sizes. Both cache modules
must be the same size.
Remove the failed array controller,
replace one of the cache modules
with a different one that is of the
correct size, wait 10 seconds, and
then reinsert it, ensuring that it is
fully seated in the chassis.
62 CACHE MODULE
#<n> <n>MB
Inform
ational
The siz
eofthecachemodule
insert
ed into the indicated cache
modul
eslot.
63 VALID CACHE
DATA FOUND AT
POWER-UP
Informational
Valid host data was found in the
battery backed cache memory at
power up. This data has been
ushed to the drives.
64 CACHE DATA LOST
BATTERY DEAD
Error
Thebatteryonthecachememory
was no longer charged. If there
was data in the cache memory, it
is lost.
65 CACHE HARDWARE
ENABLED
In
formational
The
cachehardwarehadbeen
tem
porarily disabled but is now
en
abled again. This may have
been due to insufcient charge on
the batteries that are now charged
to capacity.
11 4