HP StorageWorks 1510i Modular Smart Array firmware 2.02 release notes (431339-002, March 2009)
• Added the following CLI command enhancements, limiting output display for the following com-
mands:
• show ip
• show arp
• show discovery
• show isn_server
• show acl_entry
• show target
• show portal
• show portal_group
• show iscsi_keys
• show initiator
• Added the following CLI command enhancements, adding the following new commands for Act-
ive/Active:
• show preferred_path; set preferred_path
• show auto_path_change; set auto_path_change
• show proxystats
• show taskstats
• Added the following ADU enhancements:
• Added Discovey, iSNS and iSNS server settings to ADU report.
• Added MIB statistics to ADU report.
• Converted index numbers in ADU report into readable form. (Instead of index numbers the
alias name is now displayed.)
• Fixed various formatting errors in ADU report. (Some IP addresses were previously displayed
in HEX.)
• Sort Statistics based on target/initiator information for CLI / ADU / SMU.
• Added route table support for SMU, ADU and CLI. (Route entries are sorted by dynamic/stat-
ic/data/loop-back entries.)
• Added fan-, cache-, power supply - information for external storage box to ADU report.
• In dual-controller configurations, added support for an active management port on each controller
with a unique IP address, subnet and VLAN.
• In dual-controller configurations, added support for unique iSNS settings for each controller.
• In dual-controller configurations, added support for unique SNMP trap destinations for each con-
troller.
Fixes
• HP StorageWorks MSA1510i firmware 2.00 upgrade is not recommended until further notice
(Customer Advisory c01539430)
• LUNs are no longer reset during expansion (Customer Advisory 640436).
• LUNs no longer become unavailable with I/O errors during a server reboot (Customer Advisory
640411).
• Idle sessions are now timed out after 10 minutes.
• No longer lose connectivity to storage LUNs on VMware ESX.
• Server reboots no longer cause multiple failovers.
4