HP StorageWorks 1510i Modular Smart Array firmware 2.0 release notes (431339-001, July 2008)

show portal_group
show iscsi_keys
show initiator
Added the following CLI command enhancements, adding the following new commands for
Active/Active:
show preferred_path; set preferred_path
show auto_path_change; set auto_path_change
show proxystats
show taskstats
Added the following ADU enhancements:
Added Discovey, iSNS and iSNS server settings to ADU report.
Added MIB statistics to ADU report.
Converted index numbers in ADU report into readable form. (Instead of index numbers
the alias name is now displayed.)
Fixed various formatting errors in ADU report. (Some IP addresses were previously displayed
in HEX.)
Sort Statistics based on target/initiator information for CLI / ADU / SMU.
Added route table support for SMU, ADU and CLI. (Route entries are sorted by
dynamic/static/data/loop-back entries.)
Added fan-, cache-, power supply - information for external storage box to ADU report.
In dual-controller congurations, added support for an active management port on each controller
with a unique IP address, subnet and VLAN.
In dual-controller congurations, added support for unique iSNS settings for each controller.
In dual-controller congurations, added support for unique SNMP trap destinations for each
controller.
Fixes
LUNs are no longer reset during expansion (Customer Advisory 640436).
LUNs no longer become unavailable with I/O errors during a server reboot (Customer Advisory
640411
).
Idle sessions are now timed out after 10 minutes.
No longer lose connectivity to storage LUNs on VMware ESX.
Serve
r reboots no longer cause multiple failovers.
Fixed popup message when changing hostname or non-ip elds on management setting screen to
warn of session loss.
Fixed incorrect display of Logical LUNs after forcwrstwrite.
Fixe
d controller reboot if portal added/deleted from other controller.
Prerequisites
MSA1510i rmware 2.0 requires the following components on the server:
Windows: Microsoft iSCSI Initiator 2.06+, MPIO software, and Microsoft Device SpecicModule
(DSM)
IMPORTANT:
Before installing and using 2.0 active/active rmware, any previous version of the Microsoft iSCSI Initiator
and MPIO software and HP DSM must be uninstalled from the server. While this can be done manually,
HP recommends using the MSA1510i Support CD version 2.0 to manage this process. An ISO image of
theCDisavailableontheMSA1510iSupportpage:h
ttp://www.hp.com/support.
VMware: VMware initiator that is native with 3.0.x
4