HP StorageWorks SFP Transceiver Replacement Instructions (April 2004)

Step 1: Removing the SFP transceiver
WARNING: To reduce the risk of injury from laser
radiation or damage to the equipment, observe the
following precautions:
Do not open any panels, operate controls, make
adjustments, or perform procedures to a laser device
other than those specified herein.
Do not stare into the laser beam when panels are
open.
1. Press the release clip on the bottom of the cable connector
1 to remove the Fibre Channel cable from the back of the
failed transceiver.
2. Pull the transceiver out of the device by pulling up and out
on the plastic tab 2.
Figure 1: Removing the SFP transceiver
Caution: Touching the end of a fibre cable damages the
cable. Whenever a fibre cable is not connected, replace
the protective covers on the ends of the cables.
Step 2: Installing the SFP transceiver
Insert the new SFP transceiver into the controller component
and replace the Fibre Channel cable.
Caution: To reduce the risk of damage to the equipment,
do not use excessive force when inserting the transceiver.
Installation is complete.
Verifying the replacement
After replacing the failed SFP transceiver:
No new error messages should be displayed on the LCD.
Unread error log messages may cause the LED to remain
lit. Be sure all error messages that have been responded to
are deleted.
Both the 1G and 2G LEDs on the Fibre Channel board
should be lit.
Returning the failed component
Please follow the return instructions provided in the new
component package.
Additional information
For additional information, refer to the MSA technical
documents web site at
http://www.hp.com/go/msa1000
.
2
15094
1