HP StorageWorks Modular Smart Array 1000 (MSA1000) Command Line Interface Reference Guide (September 2003)

Command Line Interface (CLI)
47MSA1000 Command Line Interface Reference Guide
Modifying Arrays and LUNs
Occasionally, after an array or a LUN has been created, its characteristics need to
be changed. The following changes can be made:
Adding Drives to an Array
Adding Space to a LUN
Changing the RAID Characteristics of a LUN
Changing Attributes of a LUN
Each task is discussed in the following paragraphs.
Adding Drives to an Array
To add additional physical drives to an array:
Note: Because this command affects the entire array, all LUNs made from the array are
also affected.
Basic Command
EXPAND UNIT
Example Command
CLI> EXPAND UNIT 4 DISK204-DISK207
Command Options
4—one of the LUN within the target array.
Note: Any LUN in the array can be entered to identify the array; the space is added to
the array and not the LUN.
DISK204-DISK207—the physical disks to add to the array. Disks are identified
by box number and bay number. In this example,
DISK204-DISK207 identifies
disks 4 through 7 in box number 2.
Example CLI Response
The actual new array capacity will be 3000MB.
The array with Unit 4 is being expanded.
Use “show unit 4” to monitor progress.