HP StorageWorks Modular Smart Array 1000 (MSA1000) Command Line Interface Reference Guide (September 2003)
Command Line Interface (CLI)
34 MSA1000 Command Line Interface Reference Guide
SYSTEM_NAME=”XXX”—the system name, where XXX represents any user
defined phrase, up to 20 alphanumeric characters.
READ_CACHE=50—the read cache. This value must be between 0 and 100.
WRITE_CACHE=50—the write cache. This value must be between 0 and 100.
Note: Read_cache plus write_cache must equal 100.
Example CLI Response
Global Parameters:
System Name:XXX
Rebuild Priority:HIGH
Expand Priority:HIGH
Total Cache:256MB
50% Read Cache:128MB
50% Write Cache:128MB
Setting the Controller ID
A command is used to assign a unique name to each controller installed in the
MSA1000:
Basic Command
SET THIS_CONTROLLER_ID
SET OTHER_CONTROLLER_ID
Example Command
CLI> SET THIS_CONTROLLER_ID 123
Command Options
123—the user-defined ID for the controller.
The ID can be up to 230 alphanumeric characters or a decimal number in the
range of 0 though 65535. In this example, the controller ID will be changed to
123.
Example CLI Response
CLI> SET THIS_CONTROLLER_ID 123
Controller identifier 123 created.