HP StorageWorks Modular Smart Array 1000 Configuration Procedures for HP-UX Addendum (365448-001, April 2004)

Fibre Channel switched fabric deployments
6 Modular Smart Array 1000 Configuration Procedures - for HP-UX Addendum
Note: The MSA1000 displays the message FIRMWARE FLASH STARTED when the
download begins and
FIRMWARE FLASH DONE when the download is complete.
6. When the MSA1000 controller displays FIRMWARE FLASH DONE, power cycle
the MSA1000.
When the MSA1000 completes its startup routine, the MSA1000 STARTUP
COMPLETE message is displayed.
7. Verify that the controller firmware was updated by entering the
SHOW INQUIRY command within the SCU and reading the display.
Example command, using the sample information in Table 2:
# scu -f /dev/rscsi/c5t0d0 show inquiry
The following information is displayed:
Inquiry Information:
Peripheral Device Type: Oxc <Array Controller>
Peripheral Qualifier: 0 <Peripheral Device Connected>
Device Type Modifier: 0
Removable Media: No
ANSI Version: 4 <Complies to ANSI X3.351-200x, SPC-2>
ECMA Version: 0
ISO Version: 0
Response Data Format: 2 <SCSI-2)
Terminate I/O Process: No
Additional Length: 247
Reserved (byte 5): 0x80
Soft Reset Support: No
Target Transfer Disable: No
Linked Command Support: No
Synchronous Data Transfers: No
Support for 16 Bit Transfers: No
Support for 32 Bit Transfers: No
Relative Addressing Support: No
Vendor Identification: MSA1000
Firmware Revision Level: 4.30
Vendor Specific Data: 35 30 44 39 49 50 30 33 56 00 00