Migrating to active/active controllers in Windows environments 33
8
Verify Cluster functionality:
• From the server console desktop, select Start>Run.
• In the Run window, enter cluadmin. and then click OK to open the Cluster
Administrator Utility.
• In the right pane, right-click each of the cluster groups and select Move to move
each group to this server node.
Note: Skip this step if this is the only node running in the cluster.
• Verify that each cluster group is online and is owned by this server node.
• Close the Cluster Administrator Utility.
F
9
Verify that the HP MPIO DSM Manager can access the MSA disk array:
• From the server console desktop, select Start>Run.
• In the Run window, enter compmgmt.msc and then click OK to open the Computer
Management Utility.
• In the left pane, click Computer Management>Storage>HP MPIO DSM Manager.
• Verify that the HP MPIO DSM Manager can locate and access the updated MSA
disk array.
• Close the Computer Management window.
F
10
Verify that all standalone and cluster-aware applications are functioning properly.
F
11
Verify that users and applications can access MSA disk array.
F
12
Go to post-migration set 1 to repeat the post-migration procedures on
other server nodes within the cluster.
F
13
Review the MSA1000/1500 active/active controllers best practices guide to
maximize system performance and high availability.
F
Step Description (continued) Check