HP StorageWorks 1000/1500 Modular Smart Array application note: Migrating to active/active controllers in Windows environments (400678-002, October 2006)

Migrating to active/active controllers in Windows environments 33
8
Verify Cluster functionality:
From the server console desktop, select Start>Run.
In the Run window, enter cluadmin. and then click OK to open the Cluster
Administrator Utility.
In the right pane, right-click each of the cluster groups and select Move to move
each group to this server node.
Note: Skip this step if this is the only node running in the cluster.
Verify that each cluster group is online and is owned by this server node.
Close the Cluster Administrator Utility.
F
9
Verify that the HP MPIO DSM Manager can access the MSA disk array:
From the server console desktop, select Start>Run.
In the Run window, enter compmgmt.msc and then click OK to open the Computer
Management Utility.
In the left pane, click Computer Management>Storage>HP MPIO DSM Manager.
Verify that the HP MPIO DSM Manager can locate and access the updated MSA
disk array.
Close the Computer Management window.
F
10
Verify that all standalone and cluster-aware applications are functioning properly.
F
11
Verify that users and applications can access MSA disk array.
F
12
Go to post-migration set 1 to repeat the post-migration procedures on
other server nodes within the cluster.
F
13
Review the MSA1000/1500 active/active controllers best practices guide to
maximize system performance and high availability.
F
Step Description (continued) Check