HP StorageWorks 1000/1500 Modular Smart Array application note: Migrating to active/active controllers in Windows environments (400678-002, October 2006)
Table Of Contents

Migrating to active/active controllers in Windows environments 11
4
(For systems with HP Secure Path MPIO software only)
Disable HP Secure Path services and drivers:
• From the server console desktop, select Start>Run.
• In the Run window, enter services.msc and then click OK to open the Services
Utility.
• In the right pane, double-click Compaq HS_ Service.
• Change the Startup type from Automatic to Disabled.
• Click Stop to stop the service.
• Click OK to close the window.
• In the right pane, double-click Secure Path Agent.
• Change the Startup type from Automatic to Disabled.
• Click Stop to stop the service.
• Click OK to close the window.
• If HP Secure Path Manager software is installed, double-click Element Manager for
Secure Path in the right pane to open the Element Manager for Secure Path
Properties window.
• Change the Startup type from Automatic to Disabled.
• Click Stop to stop the service.
• Click OK to close the window.
• Close the Services Utility.
• From the server console desktop, select Start>Run.
• In the Run window, enter devmgmt.msc and then click OK to open the Device
Manager Utility.
• Select SCSI and RAID controllers, right-click the Compaq Secure Path Disk Bus
device, and then select Disable.
• Click Yes when the pop-up warning is displayed.
• Close the Device Manager Utility.
• Click No if a pop-up window opens asking to restart the server.
F
5
Insert the HP StorageWorks Modular Smart Array 1000/1500 Support Software CD
and install the required applications and drivers from the CD:
• Qlogic/Emulex HBA driver (restart the server if required)
• Array Configuration Utility (ACU) software
• (Optional) Array Configuration Utility CLI (ACUCLI) software
• (Optional) Array Diagnostics Utility (ADU) software
• (Optional) HP MPIO Full-Featured DSM for Windows (restart the server if required)
• (Optional) HP MPIO DSM Manager
F
6
Remove the HP StorageWorks Modular Smart Array 1000/1500 Support Software
CD from the CD-ROM drive.
F
Step Description (continued) Check