HP StorageWorks 1000 Modular Smart Array application note: Migrating to active/active controllers in Tru64 UNIX environments (434886-001, October 2006)

Migrating to active/active controllers in Tru64 UNIX environments 7
Upgrading the MSA to active/active
9
View and record the current configuration of all hard drives and associated LUNs.
From the MSA Command Line Interface (CLI), enter: show tech_support
F
10
Verify that supported HBA drivers and FC HBA firmware are installed as listed in the
Compatibility Guide on the MSA website:
MSA 1500 website: http://www.hp.com/go/msa1500cs
MSA 1000 website: http://www.hp.com/go/msa1000
The firmware version of the FC HBA can be viewed in the /var/adm/messages file
or the console log when the server boots up.
To see the currently-installed driver version, enter the following from the V5.1B
operating system: #grep Rev /var/adm/messages
If needed, obtain updated HBA drivers and firmware from the HP website:
http://www.software.hp.com
.
The FC HBA drivers are contained in the Tru64 UNIX patch kits. The minimum
supported patch kit for Tru64 V5.1B is PK4 / BL25.
The FC HBA firmware is available on the Alpha SRM firmware Update CD.
F
Step Description (continued) Check
Step Description Check
1
Notify all system administrators with systems connected to the MSA SAN fabric that the
disk array will temporarily be offline.
F
2
Download the new firmware to the MSA controller and any attached MSA20 storage
enclosures using the Tru64 MSA firmware upgrade procedures located in the
MSA1000/1500 Firmware Updating Guide.
IMPORTANT: Do not power cycle the MSA at this time as indicated in the
MSA1000/1500 Firmware Updating Guide.
F
3
If the operating system is installed on the MSA go to Step 4.
If a second FC HBA is not installed in the server(s) go to step 4.
If the operating system is not installed on the MSA, and a second FC HBA is
already configured, go to Step 7.
F
4
Shutdown all production servers attached to the MSA SAN fabric.
F
5
If a second FC HBA path has not been configured yet, power off the server(s) and
install the second or subsequent FC HBA adapter and power on the server.
F
6
Record the WWID of the new FC HBA.
From the Alpha SRM console, enter: #show dev p
NOTE: Check the firmware version of the new FC HBA by booting the Alpha SRM
firmware update CD. Update the firmware if necessary.
F