HP StorageWorks 1000 Modular Smart Array application note: Migrating to active/active controllers in OpenVMS environments (434885-001, October 2006)
6
Step Description Check
1
Review or obtain the following documents on the MSA website:
• QuickSpecs
• Command Line Interface User Guide
• MSA1000/1500 Firmware Updating Guide
MSA 1500 website: http://www.hp.com/go/msa1500cs
MSA 1000 website: http://www.hp.com/go/msa1000
Obtain the latest active/active controller firmware files (version 7.0 or later).
Go to the MSA website, and then click Software, firmware & drivers.
F
2
Backup the OS and data volumes.
F
3
Verify successful backup of OS and data volumes.
F
4
Document and diagram the existing switch fabric configuration.
F
5
Record existing device names and Fibre Channel HBA hardware paths of servers. (This
information is required to verify the configuration after the firmware upgrade process is
complete.)
From the server console, enter: show dev dga/full/out=mydisk_config.txt
F
6
Record the World Wide Port Names (WWPN) of the Fibre Channel HBAs connected
to the MSA. (This information is required to verify the configuration after the firmware
upgrade process is complete.)
• From the server console, enter: show dev fg/full/out=myHBA_config.txt
and make a note of the ports.
• From the server console, enter:
show dev gg/full/out=myctrldevs_config.txt
This command displays a listing of current command devices.
F
7
View and record the current configuration of all hard drives and associated LUNs.
From the MSA Command Line Interface (CLI), enter: show tech_support
F
8
If needed, install additional supported HP Fibre Channel HBAs in the server.
F
9
Verify that the latest HBA firmware and EFI drivers (Integrity Servers only) are installed.
Go to the HP OpenVMS systems website, and then select your server family from the
Related links list.
HP OpenVMS systems website: http://h71000.www7.hp.com/
NOTE: When selecting firmware versions under Integrity servers, OpenVMS uses the
same versions as HP-UX. The HPUX version should be selected.
F
10
The fibre channel drivers and multipath software drivers are an integral part of the
OVMS operating system. Verify that the latest OpenVMS fibre channel drivers are
installed. Download the latest FIBRE_SCSI patch kit for your operating system version
from the HP IT Resource Center website: http://www1.itrc.hp.com/
F