HSG80 ACS Solution Software V8.6 for IBM AIM Installation and Configuration Guide
Table Of Contents
- HSG80 ACS Solution Software Version 8.6 for IBM AIX
- Contents
- Figures
- Tables
- About this Guide
- Chapter 1
- Planning a Subsystem
- Chapter 2
- Planning Storage
- Where to Start
- Configuration Rules
- Device PTL Addressing Convention
- Determining Storage Requirements
- Choosing a Container Type
- Creating a Storageset Profile
- Storageset Planning Considerations
- Storageset Expansion Considerations
- Partition Planning Considerations
- Changing Characteristics through Switches
- Storageset and Partition Switches
- Initialization Switches
- Unit Switches
- Storage Maps
- Chapter 3
- Preparing the Host System
- Chapter 4
- Installing and Configuring the HS-Series Agent
- Why Use StorageWorks Command Console (SWCC)?
- Installation and Configuration Overview
- About the Network Connection for the Agent
- Before Installing the Agent
- Installing and Configuring the Agent
- Running the Agent
- Reconfiguring the Agent
- Uninstall Agent, Storageworks Software, and Cambex Driver.
- High Availability Cluster Multi-Processor (HACMP)
- Enabler Software
- General Note on Software Installation
- SWCC Clients
- Running the Agent
- HACMP Implementation for the Agent
- Prerequisites
- Implementation
- Installing the Agent on an HACMP Cluster
- Installing and Configuring the Client on an HACMP cluster
- Operation of the Agent on an HACMP Cluster
- Normal Operation of the Agent on an HACMP Cluster
- Starting, Stopping and Checking for the Agent
- Password and Notification
- Client Functions and Storage Subsystem Options
- Failover with Agent as Part of a Resource Group
- Client IP Address
- Event Scripts
- Notification within HACMP
- Node Isolation Recovery
- Failure of the Agent
- Polling all nodes in cluster for presence of a running Agent
- Restarting the Agent on surviving node
- Notification
- Supporting Tools
- HACMP for AIX Primary Event Scripts
- HACMP for AIX Secondary Event Scripts
- Chapter 5
- Configuration Procedures
- Establishing a Local Connection
- Setting Up a Single Controller
- Setting Up a Controller Pair
- Configuring Devices
- Configuring a Stripeset
- Configuring a Mirrorset
- Configuring a RAIDset
- Configuring a Striped Mirrorset
- Configuring a Single-Disk Unit (JBOD)
- Configuring a Partition
- Assigning Unit Numbers and Unit Qualifiers
- Configuration Options
- Chapter 6
- Verifying Storage Configuration from the Host
- Chapter 7
- Configuration Example Using CLI
- Chapter 8
- Backing Up the Subsystem, Cloning Data for Backup, and Moving Storagesets
- Appendix A
- Subsystem Profile Templates
- Storageset Profile
- Storage Map Template 1 for the BA370 Enclosure
- Storage Map Template 2 for the second BA370 Enclosure
- Storage Map Template 3 for the third BA370 Enclosure
- Storage Map Template 4 for the Model 4214R Disk Enclosure
- Storage Map Template 5 for the Model 4254 Disk Enclosure
- Storage Map Template 6 for the Model 4310R Disk Enclosure
- Storage Map Template 7 for the Model 4350R Disk Enclosure
- Storage Map Template 8 for the Model 4314R Disk Enclosure
- Storage Map Template 9 for the Model 4354R Disk Enclosure
- Appendix B
- Installing, Configuring, and Removing the Client
- Appendix C
- Exploitation of the CLONE and SNAPSHOT Functions of the HSG80 in an AIX Environment
- Glossary
- Index
2–34 HSG80 ACS Solution Software Version 8.6 for IBM AIX Installation and Configuration Guide
■ Unit D101 is a 2-member striped mirrorset named S1. S1 consists of M1 and M2:
❏ M1 is a 2-member mirrorset consisting of Disk10100 and Disk20100.
❏ M2 is a 2-member mirrorset consisting of Disk30100 and Disk40100.
■ Unit D102 is a 2-member mirrorset named M3. M3 consists of Disk10200 and
Disk20200.
■ Unit D103 is a 2-member mirrorset named M4. M4 consists of Disk30200 and
Disk40200.
■ Unit D104 is 3-member stripeset named S2. S2 consists of Disk10300, Disk20300, and
Disk30300.
■ Unit D105 is a single (JBOD) disk named Disk40300.
■ Unit D106 is a 3-member RAID 3/5 storageset named R2. R2 consists of Disk10400,
Disk20400, and Disk30400.
■ Unit D107 is a single (JBOD) disk named Disk40400.
■ Unit D108 is a 4-member stripeset named S3. S3 consists of Disk10500, Disk20500,
Disk30500, and Disk40500.
■ Unit D1 is a 2-member striped mirrorset named S4. S4 consists of M5 and M6:
❏ M5 is a 2-member mirrorset consisting of Disk10800 and Disk20800.
❏ M6 is a 2-member mirrorset consisting of Disk30800 and Disk40800.
■ Unit D2 is a 4-member RAID 3/5 storageset named R3. R3 consists of Disk10900,
Disk20900, Disk30900, and Disk40900.
■ Unit D3 is a 4-member stripeset named S5. S5 consists of Disk11000, Disk21000,
Disk31000, and Disk41000.
■ Unit D4 is a 2-member mirrorset named M7. M7 consists of Disk11100 and
Disk21100.
■ Unit D5 is a 2-member stripeset named S6. S6 consists of Disk31100 and Disk41100.
■ Unit D6 is a 4-member RAID 3/5 storageset named R4. R4 consists of Disk11200,
Disk21200, Disk31200, and Disk41200.
■ Unit D7 is a 2-member mirrorset named M8. M8 consists of Disk11300 and
Disk21300.
■ Unit D8 is a 2-member stripeset named S7. S7 consists of Disk31300 and Disk41300.
■ Unit D9 is a 4-member Raidset named R5. R5 consists of Disk41400, Disk11400,
Disk21400 and Disk31400.
■ Disk11500, Disk21500, Disk31500, and Disk41500 are spareset members.