HSG80 ACS Solution Software V8.6 for IBM AIM Installation and Configuration Guide
Table Of Contents
- HSG80 ACS Solution Software Version 8.6 for IBM AIX
- Contents
- Figures
- Tables
- About this Guide
- Chapter 1
- Planning a Subsystem
- Chapter 2
- Planning Storage
- Where to Start
- Configuration Rules
- Device PTL Addressing Convention
- Determining Storage Requirements
- Choosing a Container Type
- Creating a Storageset Profile
- Storageset Planning Considerations
- Storageset Expansion Considerations
- Partition Planning Considerations
- Changing Characteristics through Switches
- Storageset and Partition Switches
- Initialization Switches
- Unit Switches
- Storage Maps
- Chapter 3
- Preparing the Host System
- Chapter 4
- Installing and Configuring the HS-Series Agent
- Why Use StorageWorks Command Console (SWCC)?
- Installation and Configuration Overview
- About the Network Connection for the Agent
- Before Installing the Agent
- Installing and Configuring the Agent
- Running the Agent
- Reconfiguring the Agent
- Uninstall Agent, Storageworks Software, and Cambex Driver.
- High Availability Cluster Multi-Processor (HACMP)
- Enabler Software
- General Note on Software Installation
- SWCC Clients
- Running the Agent
- HACMP Implementation for the Agent
- Prerequisites
- Implementation
- Installing the Agent on an HACMP Cluster
- Installing and Configuring the Client on an HACMP cluster
- Operation of the Agent on an HACMP Cluster
- Normal Operation of the Agent on an HACMP Cluster
- Starting, Stopping and Checking for the Agent
- Password and Notification
- Client Functions and Storage Subsystem Options
- Failover with Agent as Part of a Resource Group
- Client IP Address
- Event Scripts
- Notification within HACMP
- Node Isolation Recovery
- Failure of the Agent
- Polling all nodes in cluster for presence of a running Agent
- Restarting the Agent on surviving node
- Notification
- Supporting Tools
- HACMP for AIX Primary Event Scripts
- HACMP for AIX Secondary Event Scripts
- Chapter 5
- Configuration Procedures
- Establishing a Local Connection
- Setting Up a Single Controller
- Setting Up a Controller Pair
- Configuring Devices
- Configuring a Stripeset
- Configuring a Mirrorset
- Configuring a RAIDset
- Configuring a Striped Mirrorset
- Configuring a Single-Disk Unit (JBOD)
- Configuring a Partition
- Assigning Unit Numbers and Unit Qualifiers
- Configuration Options
- Chapter 6
- Verifying Storage Configuration from the Host
- Chapter 7
- Configuration Example Using CLI
- Chapter 8
- Backing Up the Subsystem, Cloning Data for Backup, and Moving Storagesets
- Appendix A
- Subsystem Profile Templates
- Storageset Profile
- Storage Map Template 1 for the BA370 Enclosure
- Storage Map Template 2 for the second BA370 Enclosure
- Storage Map Template 3 for the third BA370 Enclosure
- Storage Map Template 4 for the Model 4214R Disk Enclosure
- Storage Map Template 5 for the Model 4254 Disk Enclosure
- Storage Map Template 6 for the Model 4310R Disk Enclosure
- Storage Map Template 7 for the Model 4350R Disk Enclosure
- Storage Map Template 8 for the Model 4314R Disk Enclosure
- Storage Map Template 9 for the Model 4354R Disk Enclosure
- Appendix B
- Installing, Configuring, and Removing the Client
- Appendix C
- Exploitation of the CLONE and SNAPSHOT Functions of the HSG80 in an AIX Environment
- Glossary
- Index
1–14 HSG80 ACS Solution Software Version 8.6 for IBM AIX Installation and Configuration Guide
Assigning Unit Numbers
The controller keeps track of the unit with the unit number. The unit number can be from
0−199 prefixed by a D, which stands for disk drive. A unit can be presented as different
LUNs to different connections. The interaction of a unit and a connection is determined by
several factors:
■ Failover mode of the controller pair
■ The ENABLE_ACCESS_PATH and PREFERRED_PATH switches in the ADD UNIT (or
SET unit) commands
■ The UNIT_OFFSET switch in the ADD CONNECTIONS (or SET connections) commands
■ The controller port to which the connection is attached
■ The SCSI_VERSION switch of the SET THIS_CONTROLLER/OTHER_CONTROLLER command
The considerations for assigning unit numbers are discussed in the following sections.
Matching Units to Host Connections in Transparent Failover
Mode
In transparent failover mode, the ADD UNIT command creates a unit for host connection to
access and assigns it to either port 1 of both controllers or to port 2 of both controllers.
Unit numbers are assigned to ports as follows:
■ 0−99 are assigned to host port 1 of both controllers.
■ 100−199 are assigned to host port 2 of both controllers.
For example, unit D2 is on port 1, and unit D102 is on port 2.
The LUN number that a host connection assigns to a unit is a function of the
UNIT_OFFSET switch of the
ADD (or SET) CONNECTIONS command. The relationship of
offset, LUN number, and unit number is shown in the following equation:
LUN number = unit number – offset
Where. . .
❏ LUN number is relative to the host (what the host sees the unit as)
❏ Unit number is relative to the controller (what the controller sees the unit as)