HSG80 ACS Solution Software V8.6 for IBM AIM Installation and Configuration Guide
Table Of Contents
- HSG80 ACS Solution Software Version 8.6 for IBM AIX
- Contents
- Figures
- Tables
- About this Guide
- Chapter 1
- Planning a Subsystem
- Chapter 2
- Planning Storage
- Where to Start
- Configuration Rules
- Device PTL Addressing Convention
- Determining Storage Requirements
- Choosing a Container Type
- Creating a Storageset Profile
- Storageset Planning Considerations
- Storageset Expansion Considerations
- Partition Planning Considerations
- Changing Characteristics through Switches
- Storageset and Partition Switches
- Initialization Switches
- Unit Switches
- Storage Maps
- Chapter 3
- Preparing the Host System
- Chapter 4
- Installing and Configuring the HS-Series Agent
- Why Use StorageWorks Command Console (SWCC)?
- Installation and Configuration Overview
- About the Network Connection for the Agent
- Before Installing the Agent
- Installing and Configuring the Agent
- Running the Agent
- Reconfiguring the Agent
- Uninstall Agent, Storageworks Software, and Cambex Driver.
- High Availability Cluster Multi-Processor (HACMP)
- Enabler Software
- General Note on Software Installation
- SWCC Clients
- Running the Agent
- HACMP Implementation for the Agent
- Prerequisites
- Implementation
- Installing the Agent on an HACMP Cluster
- Installing and Configuring the Client on an HACMP cluster
- Operation of the Agent on an HACMP Cluster
- Normal Operation of the Agent on an HACMP Cluster
- Starting, Stopping and Checking for the Agent
- Password and Notification
- Client Functions and Storage Subsystem Options
- Failover with Agent as Part of a Resource Group
- Client IP Address
- Event Scripts
- Notification within HACMP
- Node Isolation Recovery
- Failure of the Agent
- Polling all nodes in cluster for presence of a running Agent
- Restarting the Agent on surviving node
- Notification
- Supporting Tools
- HACMP for AIX Primary Event Scripts
- HACMP for AIX Secondary Event Scripts
- Chapter 5
- Configuration Procedures
- Establishing a Local Connection
- Setting Up a Single Controller
- Setting Up a Controller Pair
- Configuring Devices
- Configuring a Stripeset
- Configuring a Mirrorset
- Configuring a RAIDset
- Configuring a Striped Mirrorset
- Configuring a Single-Disk Unit (JBOD)
- Configuring a Partition
- Assigning Unit Numbers and Unit Qualifiers
- Configuration Options
- Chapter 6
- Verifying Storage Configuration from the Host
- Chapter 7
- Configuration Example Using CLI
- Chapter 8
- Backing Up the Subsystem, Cloning Data for Backup, and Moving Storagesets
- Appendix A
- Subsystem Profile Templates
- Storageset Profile
- Storage Map Template 1 for the BA370 Enclosure
- Storage Map Template 2 for the second BA370 Enclosure
- Storage Map Template 3 for the third BA370 Enclosure
- Storage Map Template 4 for the Model 4214R Disk Enclosure
- Storage Map Template 5 for the Model 4254 Disk Enclosure
- Storage Map Template 6 for the Model 4310R Disk Enclosure
- Storage Map Template 7 for the Model 4350R Disk Enclosure
- Storage Map Template 8 for the Model 4314R Disk Enclosure
- Storage Map Template 9 for the Model 4354R Disk Enclosure
- Appendix B
- Installing, Configuring, and Removing the Client
- Appendix C
- Exploitation of the CLONE and SNAPSHOT Functions of the HSG80 in an AIX Environment
- Glossary
- Index

Planning a Subsystem 1–11
Enabling/Disabling CCL in SCSI-3 Mode
The CCL is enabled all the time. There is no option to enable/disable.
Connections
The term “connection” applies to every path between a Fibre Channel adapter in a host
computer and an active host port on a controller.
NOTE: In ACS V8.6 the maximum number of supported connections is 96.
Naming Connections
Compaq highly recommends that you assign names to connections that have meaning in
the context of your particular configuration. One system that works well is to name each
connection after its host, its adapter, its controller, and its controller host port, as follows:
Examples:
A connection from the first adapter in the host named RED that goes to port 1 of controller
A would be called RED1A1.
A connection from the third adapter in host GREEN that goes to port 2 of controller B
would be called GREEN3B2.
NOTE: Connection names can have a maximum of 9 characters.
Numbers of Connections
The number of connections resulting from cabling one adapter into a switch or hub
depends on failover mode and how many links the configuration has:
HOST1A1
HOST
NAME
PORT
CONTROLLER
ADAPTER