HSG80 ACS Solution Software V8.6 for IBM AIM Installation and Configuration Guide

Table Of Contents
62 HSG80 ACS Solution Software Version 8.6 for IBM AIX Installation and Configuration Guide
You should have an entry of type:
hdisknn Available X0-06-01-2,4 DEC HSG80 RAID Array
for each logical unit that you have created on the RAID Array.
4. If the devices were not recognized, recheck the status of the RAID controller, logical
units, and cable connections.
You can now use the System Management Interface Tool (SMIT), to make volume
groups, logical volumes and file systems using these logical units.
NOTE: If you are using HACMP cluster software, you need only perform this procedure once and
it will apply for the entire cluster. However, shared storage must have the same hdisk number
on each node in the cluster and shared volume groups, logical volumes and file systems must
be organized as elements of shared resource groups for the defined clusters. See High
Availability for Multi-Processing for AIX Installation Guide Version 4.3.