HSG80 ACS Solution Software V8.6 for IBM AIM Installation and Configuration Guide

Table Of Contents
Configuration Procedures 525
4. Verify the configuration:
SHOW STORAGESET-NAME
Changing Switches for a Storageset or Device
You can optimize a storageset or device at any time by changing the switches that are
associated with it. Remember to update the storageset profile when changing its switches.
Displaying the Current Switches
To display the current switches for a storageset or single-disk unit, enter a SHOW command,
specifying the FULL switch:
SHOW STORAGESET-NAME
or
SHOW DEVICE-NAME FULL
Changing RAIDset and Mirrorset Switches
Use the SET storageset-name command to change the RAIDset and Mirrorset switches
associated with an existing storageset.
For example, the following command changes the replacement policy for RAIDset RAID1
to BEST_FIT:
SET RAID1 POLICY=BEST_FIT
Changing Device Switches
Use the SET device-name command to change the device switches.
For example, to request a data transfer rate of 20 MHz for DISK10000:
SET DISK10000 TRANSFER_RATE_REQUESTED=20MHZ