HSG80 ACS Solution Software V8.6 for IBM AIM Installation and Configuration Guide
Table Of Contents
- HSG80 ACS Solution Software Version 8.6 for IBM AIX
- Contents
- Figures
- Tables
- About this Guide
- Chapter 1
- Planning a Subsystem
- Chapter 2
- Planning Storage
- Where to Start
- Configuration Rules
- Device PTL Addressing Convention
- Determining Storage Requirements
- Choosing a Container Type
- Creating a Storageset Profile
- Storageset Planning Considerations
- Storageset Expansion Considerations
- Partition Planning Considerations
- Changing Characteristics through Switches
- Storageset and Partition Switches
- Initialization Switches
- Unit Switches
- Storage Maps
- Chapter 3
- Preparing the Host System
- Chapter 4
- Installing and Configuring the HS-Series Agent
- Why Use StorageWorks Command Console (SWCC)?
- Installation and Configuration Overview
- About the Network Connection for the Agent
- Before Installing the Agent
- Installing and Configuring the Agent
- Running the Agent
- Reconfiguring the Agent
- Uninstall Agent, Storageworks Software, and Cambex Driver.
- High Availability Cluster Multi-Processor (HACMP)
- Enabler Software
- General Note on Software Installation
- SWCC Clients
- Running the Agent
- HACMP Implementation for the Agent
- Prerequisites
- Implementation
- Installing the Agent on an HACMP Cluster
- Installing and Configuring the Client on an HACMP cluster
- Operation of the Agent on an HACMP Cluster
- Normal Operation of the Agent on an HACMP Cluster
- Starting, Stopping and Checking for the Agent
- Password and Notification
- Client Functions and Storage Subsystem Options
- Failover with Agent as Part of a Resource Group
- Client IP Address
- Event Scripts
- Notification within HACMP
- Node Isolation Recovery
- Failure of the Agent
- Polling all nodes in cluster for presence of a running Agent
- Restarting the Agent on surviving node
- Notification
- Supporting Tools
- HACMP for AIX Primary Event Scripts
- HACMP for AIX Secondary Event Scripts
- Chapter 5
- Configuration Procedures
- Establishing a Local Connection
- Setting Up a Single Controller
- Setting Up a Controller Pair
- Configuring Devices
- Configuring a Stripeset
- Configuring a Mirrorset
- Configuring a RAIDset
- Configuring a Striped Mirrorset
- Configuring a Single-Disk Unit (JBOD)
- Configuring a Partition
- Assigning Unit Numbers and Unit Qualifiers
- Configuration Options
- Chapter 6
- Verifying Storage Configuration from the Host
- Chapter 7
- Configuration Example Using CLI
- Chapter 8
- Backing Up the Subsystem, Cloning Data for Backup, and Moving Storagesets
- Appendix A
- Subsystem Profile Templates
- Storageset Profile
- Storage Map Template 1 for the BA370 Enclosure
- Storage Map Template 2 for the second BA370 Enclosure
- Storage Map Template 3 for the third BA370 Enclosure
- Storage Map Template 4 for the Model 4214R Disk Enclosure
- Storage Map Template 5 for the Model 4254 Disk Enclosure
- Storage Map Template 6 for the Model 4310R Disk Enclosure
- Storage Map Template 7 for the Model 4350R Disk Enclosure
- Storage Map Template 8 for the Model 4314R Disk Enclosure
- Storage Map Template 9 for the Model 4354R Disk Enclosure
- Appendix B
- Installing, Configuring, and Removing the Client
- Appendix C
- Exploitation of the CLONE and SNAPSHOT Functions of the HSG80 in an AIX Environment
- Glossary
- Index
Configuration Procedures 5–15
18. Verify node ID, allocation class, SCSI version, failover mode, identifier, and port
topology. The following display is a sample result of a
SHOW THIS command, with the
areas of interest in bold.
Controller:
HSG ZG09030200 Software V85L, Hardware E01
NODE_ID = 5000-1FE1-0000-00A0
ALLOCATION_CLASS = 0
SCSI_VERSION = 2
Device Port SCSI address 6
Time: 10-Mar-1999:12:30:34
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0000-0001
PORT_1_TOPOLOGY = FABRIC (fabric up)
Address = 011121
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0000-0002
PORT_2_TOPOLOGY = FABRIC (standby)
Address = 011221
Cache: 128 megabyte write cache, version 0012 Cache is GOOD
..........
19. Turn on the switches, if not done previously.
Plug in the FC Cable and Verify Connections
20. Plug the FC cable from the first host adapter into the switch or hub. Enter a SHOW
CONNECTIONS
command to view the connection table:
HSG > SHOW CONNECTIONS
The first connection will have one or more entries in the connection table. Each
connection will have a default name of the form !NEWCONxx, where xx is a number
representing the order in which the connection was added to the connection table.
For a description of why plugging in one adapter can result in multiple connections,
see “Numbers of Connections,” page 1–11.