HSG80 ACS Solution Software V8.6 for IBM AIM Installation and Configuration Guide

Table Of Contents
514 HSG80 ACS Solution Software Version 8.6 for IBM AIX Installation and Configuration Guide
Set Time and Verify All Commands
14. Set the time on the controller by entering the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
15. Use the FRUTIL utility to set up the battery discharge timer. Enter the following
command to start FRUTIL:
HSG> RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer Y:
Do you intend to replace this controller's cache battery? Y/N [N] Y
FRUTIL will print out a procedure, but will not give you a prompt. Ignore the
procedure and press Enter.
16. Set up any additional optional controller settings, such as changing the CLI prompt.
See the
SET THIS CONTROLLER/OTHER CONTROLLER command in the Compaq StorageWorks
HSG80 Array Controller ACS Version 8.6 CLI Reference Guide for the format of
optional settings. Perform this step on both controllers.
17. Verify that all commands have taken effect by entering the following command:
HSG> SHOW THIS