HSG80 ACS Solution Software V8.6 for IBM AIM Installation and Configuration Guide

Table Of Contents
Configuration Procedures 57
14. Restart the controllers for the new settings to take effect, by entering the following
command:
HSG> RESTART OTHER_CONTROLLER
HSG> RESTART THIS_CONTROLLER
It takes about one minute for the CLI prompt to come back after a RESTART command.
Set Time and Verify all Commands
15. Set the time on the controller by entering the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
16. Use the FRUTIL utility to set up the battery discharge timer. Enter the following
command to start FRUTIL:
HSG > RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer Y:
Do you intend to replace this controller's cache battery? Y/N [N] Y
FRUTIL will print out a procedure, but will not give you a prompt. Ignore the
procedure and press the Enter key.
17. Set up any additional optional controller settings, such as changing the CLI prompt.
See the
SET THIS CONTROLLER/OTHER CONTROLLER command in the Compaq StorageWorks
HSG80 Array Controller ACS Version 8.6 CLI Reference Guide for the format of
optional settings.
18. Verify that all commands have taken effect. Use the following command:
HSG> SHOW THIS
Verify node ID, allocation class, SCSI version, failover mode, identifier, and port
topology.