HSG80 ACS Solution Software V8.6 for IBM AIM Installation and Configuration Guide

Table Of Contents
56 HSG80 ACS Solution Software Version 8.6 for IBM AIX Installation and Configuration Guide
6. To set the prompt to the HSG80 controller, enter:
SET THIS_CONTROLLER PROMPT=HSG>
7. Clear the persistent error messages by entering the following command:
HSG> CLEAR CLI
8. Set the node by acquiring the Worldwide Name (WWN) node number and checksum
from the enclosed label (located on the top surface of the controller enclosure), and by
entering the following command:
HSG> SET THIS_CONTROLLER NODE=NNNN-NNNN-NNNN-NNNN CHECKSUM
9. Enable the command console LUN by entering the following command:
HSG> SET THIS_CONTROLLER COMMAND_CONSOLE_LUN
10. Set the port topology offline by entering the following command:
HSG> SET THIS_CONTROLLER PORT_1_TOPOLOGY=OFFLINE
HSG> SET THIS_CONTROLLER PORT_2_TOPOLOGY=OFFLINE
11. Set the port topology by entering the following command:
HSG> SET THIS_CONTROLLER PORT_1_TOPOLOGY=FABRIC
HSG> SET THIS_CONTROLLER PORT_2_TOPOLOGY=FABRIC
See Table 51 on page 5 for an example of LOOP_HARD topology setup.
12. Set the SCSI version by entering the following command:
HSG> SET THIS_CONTROLLER SCSI VERSION=SCSI-2
13. Determine if the operating system set for the online controller connection is WINNT,
by entering the following command:
HSG> SHOW CONNECTIONS
Although an IBM operating system entry exists in the CLI and SWCC for the fibre
channel connection, use default setting WINNT for operation with your IBM host. The
IBM setting may cause problems when LUNs are not available to AIX or during
controller failover. If so, use:
HSG> SET !NEWCONxx OPERATING_SYSTEM=WINNT
where: xx is the online connection ID produced in the SHOW CONNECTIONS command
above.
NOTE: Further information on command syntax can be found in the Compaq StorageWorks
HSG80 Array Controller ACS Version 8.6 CLI Reference Guide.