Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide

56 HSG60 ACS Solution Software Version 8.6 for SGI Irix Installation and Configuration Guide
6. Set the topology for the controller. If both ports are used, set topology for both ports:
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
If the controller is not new from the factory, it may have another topology set, in which
case these commands will result in an error message. If this happens, take both ports
offline first, then reset the topology:
SET THIS PORT_1_TOPOLOGY=OFFLINE
SET THIS PORT_2_TOPOLOGY=OFFLINE
SET THIS PORT_1_TOPOLOGY=FABRIC
SET THIS PORT_2_TOPOLOGY=FABRIC
Restart the Controllers
7. Restart the controller, using the following command:
RESTART THIS
It takes about one minute for the CLI prompt to come back after a RESTART
command.
Set Time and Verify All Commands
8. Set the time on the controller using the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
9. Use the FRUTIL utility to set up the battery discharge timer. Enter the following
command to start FRUTIL:
RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer Y:
Do you intend to replace this controller's cache battery? Y/N [N] Y
FRUTIL will print out a procedure, but won't give you a prompt. Ignore the procedure
and just press enter.
10. Set up any additional optional controller settings, such as changing the CLI prompt.
See the SET this_controller/other controller command in the Compaq StorageWorks
HSG60 Array Controller ACS Version 8.6 CLI Reference Guide for the format of
optional settings.
11. Verify that all commands have taken effect. Use the following command:
SHOW THIS