Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide

Configuration Procedures 55
See Worldwide Names (Node IDs and Port IDs), page 117, for the location of the
sticker.
The node ID is located in the third line of the SHOW THIS result:
HSG60> show this
Controller:
HSG60 ZG80900583 Software V8.6L-0, Hardware E11
NODE_ID = 5000-1FE1-0001-3F00
ALLOCATION_CLASS = 0
If the node ID is present, go to step 6.
If the node ID is all zeroes, enter the node ID and checksum, which are located on
a sticker on the controller enclosure. Use the following syntax to enter the node ID:
SET THIS NODE_ID=NNNN-NNNN-NNNN-NNNN nn
NNNN-NNNN-NNNN-NNNN is the node ID, and nn is the checksum.
2. If the controller you are working with is not new from the factory, enter the following
command to take it out of any failover mode that may have been configured
previously:
SET NOFAILOVER
If the controller did have a failover mode previously set, the CLI may report an error.
Clear the error with this command:
CLEAR_ERRORS CLI
3. Enter the following command to remove any previously configured connections:
SHOW CONNECTIONS
A list of named connections, if any, is displayed.
4. Delete these connections by entering the following command:
DELETE !NEWCON01
Repeat this delete command for each of the listed connections. When completed, no
connections will be displayed.
Configure Controller Settings
5. Set the SCSI version to SCSI-2 , using the following command.
SET THIS SCSI_VERSION=SCSI-2
Setting the SCSI version to SCSI-3 does not make the controller fully compliant with
the SCSI-3 standards.