Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide

Preparing the Host System 33
5. Change to that directory.
# cd HSG60
6. If the SGI-Irix automounter does not mount the CD-ROM, use the following
command:
# mount -t iso9660 -r /dev/rdsk/dks0d7vol /mnt
NOTE: The name of dks0d7vol may be different on your system.
7. Extract the file archive from the CD-ROM by entering the following command:
# tar xvf /mnt/agent/sgi/stm_sgi.tar
All of the files necessary to complete the StorageWorks Software installation have now
been copied to this directory.
Executing the Installation Script
Perform the following procedure to install the StorageWorks software onto the system:
1. Enter the following command and press Enter.
# ./stgwks_sgi.sh
The installation options menu appears.
2. Choose option 1 to install StorageWorks Software. The Copyright Notice and the
following information will be displayed:
Copyright Compaq Computer Corp. 1994 - 2001. All rights reserved.
Restricted Rights: Use, duplication by the U.S. Government is subject to restriction as set forth in
subparagraph (c) (1) (ii) of DFARS 252.227-7013, or in FAR 52.227-19, or in FAR 52.227-14 Alt.III, as
applicable
Portions of this software are proprietary to and embody the confidential technology of Compaq Computer
Corporation. Possession, use, or copying of this software and media is authorized only pursuant to a valid
written license from Compaq or an authorized sublicensor.
Checking User...OK
Checking Irix Revision Level...OK
Checking that Host Adapter is installed and correctly configured...OK
Copying installation files to /usr/stgwks directory...OK
StorageWorks Software Installed