Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide

122 HSG60 ACS Solution Software Version 8.6 for SGI Irix Installation and Configuration Guide
Set the connections to SGI by typing:
HSG60>SET [CONNECTIONNAME] OPERATING __SYSTEM =SGI
Repeat the command for each connection shown.
Host System Setup
Once the RAID Array has been configured, the Host System must be set up.
1. Shut down the host operating system, using your site-specific procedures. Once the
operating system has halted, power off the SGI system enclosure.
2. If necessary, install the SGI Fibre Channel host adapter, and the optical to electrical
Media Interface Adapter (MIA), using specific SGI FC-AL adapters only. The MIA
should be secured to the host adapter with its two attached fastening screws. The MIA
is available from SGI using the following part number X-F-OE-KIT
3. Before starting the Host System, connect the optical cables from the RAID Controller
to the hub or switch. Then connect the Fibre Channel Host adapter in the SGI
enclosure to the hub or switch with an optical cable.
4. Once the cables are securely connected, power on the SGI enclosure and start the
operating system.
5. Once the bootstrap process has completed, log in to the system as superuser (root).