Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide
1–20 HSG60 ACS Solution Software Version 8.6 for SGI Irix Installation and Configuration Guide
Setting the ALPA:
HSG60 >SET THIS_CONTROLLER PORT_1_AL_PA=71
HSG60 >SET THIS_CONTROLLER PORT_2_AL_PA=72
Setting the Port Topology:
HSG60>SET OTHER_CONTROLLER PORT_1_TOPOLOGY=LOOP_HARD
HSG60>SET OTHER_CONTROLLER PORT_2_TOPOLOGY=LOOP_HARD
Setting the SCSI Version:
HSG60>SET THIS_CONTROLLER SCSI_VERSION=SCSI-2
HSG60>SET THIS_CONTROLLER SCSI_VERSION=SCSI-2
If the StorageWorks Command Console (SWCC) will be used, the HSG60 Command
Console LUN must be enabled.
HSG60>SET THIS_CONTROLLER COMMAND_CONSOLE_LUN
Once all of the changes have been made, restart both controllers as follows:
HSG60>RESTART OTHER_CONTROLLER
HSG60>RESTART THIS_CONTROLLER
Once both controllers have been restarted, the connection type must be set. First examine
the connections by typing:
HSG60>SHOW CONNECTIONS
In the following command substitute the [CONNECTIONNAME] with the names shown
in the output of the
SHOW CONNECTIONS command. Set the connections to SGI by
typing:
HSG60>SET [CONNECTIONNAME] OPERATING __SYSTEM =SGI
Repeat the command for each connection shown.
Fabric Setup
Ensure that the HSG60 controllers have been set correctly for fabric. Compare the settings
displayed by the CLI with those in Table 1–3. The current settings can be obtained with
the command:
HSG60>SHOW THIS_CONTROLLER