Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide

Planning a Subsystem 119
Unit Worldwide Names (LUN IDs)
In addition, each unit has its own worldwide name, or LUN ID. This is a unique, 128-bit
value that the controller assigns at the time of unit initialization. It cannot be altered by the
user but does change when the unit is reinitialized. Use the SHOW command to list the
LUN ID.
HSG60 Setup
Before the HSG60 RAID Array can be utilized by the Host System, the array must be
properly configured. Use the HSG60 Command Line Interpreter (CLI) to complete the
following tasks.
NOTE: The exact command syntax can be found in the Compaq StorageWorks HSG60 Array
Controller ACS Version 8.6 CLI Reference Guide.
Ensure that the HSG60 controllers have been set correctly for arbitrated loop or fabric.
Compare the settings displayed by the CLI with those in Table 12 for arbitrated loop and
Table 13 for fabric. The current settings can be obtained with the command:
HSG60>SHOW THIS_CONTROLLER
Arbitrated Loop Setup
If the controller parameter settings displayed do not match those in the Recommended
Settings column in Table 12, the following CLI commands can be used to alter their
values.
NOTE: HSG60> is included in the CLI commands to show the prompt that will appear and is not
to be typed as part of the command line.
Table 12 Controller Parameters and Recommended Settings for
Arbitrated Loop
Controller Parameter Recommended Settings
PORT_1_AL_PA 71
PORT_2_AL_PA 72
PORT_1_Topology Loop_Hard
PORT_2_Topology Loop_Hard
This_Controller SCSI_Version SCSI-2
Other_Controller SCSI_Version SCSI-2