Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide

66 HSG60 ACS Solution Software Version 8.6 for SGI Irix Installation and Configuration Guide
Plug serial cable from maintenance terminal into bottom controller.
NOTE: Bottom controller (B) becomes this controller.
RUN FRUTIL
Y
SET THIS MIRRORED_CACHE
NOTE: This command causes the controllers to restart.
SET THIS PROMPT=HLNDR BOTTOM
SET OTHER PROMPT=HLNDR TOP
SHOW THIS
SHOW OTHER
Plug in the Fibre Channel cable from the adapter in host PURPLE.
SHOW CONNECTIONS
RENAME !NEWCON00 PURPLE1A1
SET PURPLE1A1 OPERATING_SYSTEM=SGI
SHOW CONNECTIONS
NOTE: Connection table sorts alphabetically.
Mark or tag both ends of Fibre Channel cables.
Plug in the Fibre Channel cable from the second adapter in host WHITE.
SHOW CONNECTIONS
Do you intend to replace this controller's cache battery? Y/N [N]
Connection
Name
Operating
System Controller Port Address Status
Unit
Offset
!NEWCON00 WNNT THIS 1 XXXXXX OL this 0
HOST_ID=XXXX-XXXX-XXXX-XXXX ADAPTER_ID=XXXX-XXXX-XXXX-XXXX
Connection
Name
Operating
System Controller Port Address Status
Unit
Offset
RED1A1 OTHER 1 XXXXXX OL other 0
HOST_ID=XXXX-XXXX-XXXX-XXXX ADAPTER_ID=XXXX-XXXX-XXXX-XXXX