Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide
5–14 HSG60 ACS Solution Software Version 8.6 for SGI Irix Installation and Configuration Guide
For a description of why plugging in one adapter can result in multiple connections,
see “Numbers of Connections,” page 1–11.
14. Rename the connection(s) to something meaningful to the system and easy to
remember. For example, to assign the name ANGEL1A1 to connection !NEWCON01,
enter:
RENAME !NEWCON01 ANGEL1A1
Compaq recommends using a naming convention, see “Naming Connections,” page
1–11.
15. Specify the operating system for the connection:
SET ANGEL1A1 OPERATING_SYSTEM=SGI
16. Verify the changes:
SHOW CONNECTIONS
Mark or tag all Fibre Channel cables at both ends for ease of maintenance.
Repeat Procedure for Each Host Adapter
17. Repeat steps 14, 15, and 16 for each of that adapter’s host connections or delete the
unwanted connections from the table.
18. For each host adapter, repeat steps 13 through 17.
Verify Installation
To verify installation for your SGI Irix host, enter the following command:
SHOW DEVICES
Configuring Devices
The disks on the device bus of the HSG60 can be configured manually or with the
CONFIG utility. The CONFIG utility is easier. Invoke CONFIG with the following
command:
RUN CONFIG
CONFIG takes about 2 minutes to discover and to map the configuration of a completely
populated storage system.