Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide
5–12 HSG60 ACS Solution Software Version 8.6 for SGI Irix Installation and Configuration Guide
Set Time and Verify All Commands
8. Set the time on the controller using the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
9. Use the FRUTIL utility to set up the battery discharge timer. Enter the following
command to start FRUTIL:
RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer “Y”:
Do you intend to replace this controller's cache battery? Y/N [N] Y
FRUTIL will print out a procedure, but will not give you a prompt. Ignore the
procedure and just press Enter.
10. Set up any additional optional controller settings, such as changing the CLI prompt.
See the
SET this_controller/other controller command in the Compaq StorageWorks
HSG60 Array Controller ACS Version 8.6 CLI Reference Guide for the format of
optional settings.
11. Verify that all commands have taken effect. Use the following command:
SHOW THIS