Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide

510 HSG60 ACS Solution Software Version 8.6 for SGI Irix Installation and Configuration Guide
Configuring a Controller Pair Using CLI
To configure a controller pair using CLI involves the following processes:
Verify the Node ID and Check for Any Previous Connections.
Configure Controller Settings.
Restart the Controller.
Plug in the FC Cable and Verify Connections.
Repeat Procedure for Each Host Adapter.
Verify Installation.
Verify the Node ID and Check for Any Previous
Connections
1. Enter a SHOW THIS command to verify the node ID:
SHOW THIS
See Worldwide Names (Node IDs and Port IDs), page 117, for the location of the
sticker.
The node ID is located in the third line of the SHOW THIS result:
HSG60> show this
Controller:
HSG60 ZG80900583 Software V8.6L-0, Hardware E11
NODE_ID = 5000-1FE1-0001-3F00
ALLOCATION_CLASS = 0
If the node ID is present, go to step 6.
If the node ID is all zeroes, enter the node ID and checksum, which are located on a
sticker on the controller enclosure. Use the following syntax to enter the node ID:
SET THIS NODE_ID=NNNN-NNNN-NNNN-NNNN nn
NNNN-NNNN-NNNN-NNNN is the node ID, and nn is the checksum.
2. If working with anything but a factory-new controller, enter the following command to
take it out of any failover mode that may have been previously configured:
SET NOFAILOVER