Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Sun Solaris Installation and Configuration Guide

Preparing the Host System 3–7
Installation Manager will verify that you are running a supported version of
Solaris, and that you have the correct patches loaded.
Installation Manager scans your system for old or incompatible drivers and it will
display a message describing which commands to use to correct the problem.
2. Follow the on-screen prompts to quit the Installation Manager.
3. Remove the offending packages.
4. Restart Installation Manager.
Installation Manager scans your system for supported adapters. When the scan is
complete, Installation Manager displays a list of supported adapters installed in your
system. After displaying a list of installed adapters, a menu appears listing the
available packages.
5. Follow the on-screen prompts to load the correct adapter driver package for the
adapters installed in your system. After the adapter driver package has successfully
loaded, you are returned to the Installation Manager menu.
6. If you have multiple adapters installed in your system, select additional adapter driver
packages until you have successfully loaded a driver package for each adapter you will
be using.
7. If you have loaded all adapter driver packages you need, install the RAIDManager
(CPQfcraid) software package. This is described in the following steps:
8. Enter the package base directory. This directory will have a “steam” subdirectory,
containing the RAIDManager files, created under it. The default directory is /opt.
Installation Manager re-scans your system for supported HBA drivers.
9. If any adapter drivers were loaded in the previous steps, you must answer “Y” to allow
the Installation Manager to re-scan your system.
10. Edit your sd.conf file. This edit can be done automatically of manually.
If you choose “M” to manually edit your sd.conf file, you can choose what FC
adapters and what targets will be supported. By default, LUNs 0 through 15 are
configured for each target that you select.
If you choose “A to automatically edit your sd.conf file, support will be added for
ALL supported FC adapters, using the default targets. These defaults are:
Loop mode: Each HBA is configured for LUNs 0 through 15 at targets 64 and
65 (corresponds with ALPAs 72 and 71).
Fabric mode: You will be prompted for the SCSI targets to bind through for
each HBA, and the Worldwide Port Names (WWPNs) to attach to.
After all files have been loaded and edited, Installation Manager exits.