Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Sun Solaris Installation and Configuration Guide

6–18 HSG60 ACS Solution Software Version 8.6 for Sun Solaris Installation and Configuration Guide
5. At the server(s), reconfigure the adapters to support loop. This is accomplished with
/opt/steam/bin/Config.sh - Option 20 Add/Change Adapters, Option 4, Modify
Adapters. This option allows the mode of the driver to be changed and the Targets to be
verified for the configuration. For each adapter that is used in the changed
configuration, this modify step must be repeated. For each server in the changed
configuration, this modify step must be repeated.
6. The changes from Step 5 require that the server(s) be rebooted (reboot -r) to
reinitialize the drivers in the correct mode and acquire the new entries/Targets from the
sd.conf files as discussed above. Shutdown and power-off the Sun server before
rebooting. We have found that the adapters must be power-cycled for reliable operation
when changing from fabric to loop mode.
7. Using the format command, verify that the units of the subsystem(s) are now available.