Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Sun Solaris Installation and Configuration Guide
6–8 HSG60 ACS Solution Software Version 8.6 for Sun Solaris Installation and Configuration Guide
Analysis
Device Class: name="sd"
The device class that we are enabling. The sd driver is the
SCSI disk, or Target driver for Solaris.
Adapter Path: parent="/iommu@f,e0000000/sbus@f,e0001000/fcaw@0,0"
Identifies the adapter, the instance and the adapter/driver
name. Note that the specific adapter path will vary with the
specific architecture of the hardware, and the specific slot
the adapter is installed in.
Target: Target=64
The default bindings for Solaris use Targets of 64 and 65 for
Arbitrated Loop. These Targets correspond with ALPAs 72
and 71. If multiple HSG60 controllers are configured on the
same loop, you should have Targets 62 and 63 defined also
(corresponding with ALPAs 74 and 73).
LUN: lun=0
The default logical units of 0..15 have been supplied and
may be extended to a total of 64.
Fabric Mappings
Two entries from a sd.conf file are shown below.
name="sd" parent="/iommu@f,e0000000/sbus@f,e0001000/fcaw@1,0" Target=64
lun=0
wwpn="5000-1fe1-0000-13f1";
…
name="sd" parent="/iommu@f,e0000000/sbus@f,e0001000/fcaw@1,0" Target=64
lun=15
ww pn="5000-1fe1-0000-13f1";
Analysis
Device Class: name="sd"
The device class that we are enabling. As with the loop
settings, the SCSI disk driver is used.
Adapter Path: parent="/iommu@f,e0000000/sbus@f,e0001000/fcaw@1,0"
Identifies the adapter, the instance and the adapter/driver
name.
Target: Target=64
The default bindings for Solaris use Targets 64 and 65 for