Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Sun Solaris Installation and Configuration Guide

5–8 HSG60 ACS Solution Software Version 8.6 for Sun Solaris Installation and Configuration Guide
If you want to communicate with the FC switches through Telnet, set an IP address for
each switch. See the manuals that came with the switches for details.
Plug in the FC Cable and Verify Connections
13. Plug in the Fibre Channel cable from the first adapter in the first host into the switch.
Enter a SHOW connections command to view the connection table:
SHOW CONNECTIONS
The first connection will have one or more entries in the connection table. Each
connection will have a default name of the form !NEWCONxx, where xx is a number
representing the order in which the connection was added to the connection table.
For an explanation about why there may be multiple connections shown for one
adapter, see page 112.
14. Rename the connection(s) to something meaningful to the system and easy to
remember. For example, to assign the name ANGEL1A1 to connection !NEWCON01,
enter:
RENAME !NEWCON01 ANGEL1A1
For a recommended naming convention, see Naming Connections, page 112.
15. Specify the operating system for the connection:
SET ANGEL1A1 OPERATING_SYSTEM=SUN
16. Verify the changes:
SHOW CONNECTIONS
Mark or tag all Fibre Channel cables at both ends for ease of maintenance.
Repeat Procedure for Each Host Adapter Connections
17. Repeat step 14, 15, and 16 for each of that adapters host connections, or delete the
unused connections from the table.
18. For each host adapter, repeat steps 13 through 17.
Connection
Name
Operating
System Controller Port Address Status
Unit
Offset
!NEWCON00 WNNT OTHER 1 200613 OL other 0
HOST_ID=XXXX-XXXX-XXXX-XXXX ADAPTER_ID=XXXX-XXXX-XXXX-XXXX