Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Linux X86 and Alpha Installation and Configuration Guide
3–2 HSG60 ACS Solution Software Version 8.6 for Linux X86 and Alpha Installation and Configuration Guide
CAUTION: Protect the host bus adapter board from electrostatic discharge by wearing
an ESD wriststrap. DO NOT remove the board from the antistatic cover until you are
ready to install it.
it.
You need the following items to begin:
■ Host bus adapter board
■ The computer hardware manual
■ Appropriate tools to service the computer
The host bus adapter board plugs into a standard PCI slot in the host computer. Refer to
the system manual for instructions on installing PCI devices.
IMPORTANT: Do not power up anything yet. For the FC switches to autoconfigure, power up
equipment in the sequence described in the next section. Also, the controllers in the subsystem
are not yet configured for compatibility with Linux.
The StorageWorks Solution Software consists of the packages as shown in Table 3–1.
Perform the following steps to install the system Manager packages onto the hard disk:
1. Mount the CD-ROM.
2. Run install_stgwks.
3. Restart your computer.
4. Configure the CPQraidsw package.
Table 3–1 StorageWorks Solution Software Packages
Package Description
CPQraidsw Agent software and system updates required for RAID system operation. This
package should always be installed.
CPQqla21x0 The HBA driver for the CPQ/Qlogic QLA2200 Fibre Channel 64-bit PCI. This package
needs to be loaded to use the QLA2200 HBA.
CPQinstall The installation scripts package.