Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Linux X86 and Alpha Installation and Configuration Guide
6–6 HSG60 ACS Solution Software Version 8.6 for Linux X86 and Alpha Installation and Configuration Guide
NOTE: This command causes the controllers to restart.
SET THIS PROMPT=“HLNDR BOTTOM”
SET OTHER PROMPT=“HLNDR TOP”
SHOW THIS
SHOW OTHER
Plug in the Fibre Channel cable from the adapter in host “PURPLE.”
SHOW CONNECTIONS
RENAME !NEWCON00 PURPLE1A1
SET PURPLE1A1 OPERATING_SYSTEM=SUN
SHOW CONNECTIONS
NOTE: Connection table sorts alphabetically.
Mark or tag both ends of Fibre Channel cables.
Plug in the Fibre Channel cable from the second adapter in host “WHITE.”
SHOW CONNECTIONS
NOTE: The offset for !NEWCONO1 is automatically set to 100 because it is plugged into host
port 2.
Connection
Name
Operating
System Controller Port Address Status
Unit
Offset
!NEWCON00 WNNT THIS 1 XXXXXX OL this 0
HOST_ID=XXXX-XXXX-XXXX-XXXX ADAPTER_ID=XXXX-XXXX-XXXX-XXXX
Connection
Name
Operating
System Controller Port Address Status
Unit
Offset
RED1A1 OTHER 1 XXXXXX OL other 0
HOST_ID=XXXX-XXXX-XXXX-XXXX ADAPTER_ID=XXXX-XXXX-XXXX-XXXX
Connection
Name
Operating
System Controller Port Address Status
Unit
Offset
!NEWCON01 WNNT THIS 2 XXXXXX OL this 100
HOST_ID=XXXX-XXXX-XXXX-XXXX ADAPTER_ID=XXXX-XXXX-XXXX-XXXX
PURPLE1A1 SUN OTHER 1 XXXXXX OL other 0
HOST_ID=XXXX-XXXX-XXXX-XXXX ADAPTER_ID=XXXX-XXXX-XXXX-XXXX