HP StorageWorks Enterprise File Services WAN Accelerator 2.1 Command Line Interface Reference Guide (November 2005)
140 4 - CONFIGURATION-MODE COMMANDS
Syntax stats alarm {<type> <options>}
Example
minna (config) # stats alarm bypass enable
minna (config) #
stats chd
Description Sets computed historical data points.
Syntax stats chd <CHD ID> clear
Parameters
Example
minna (config) # stats chd rbt_month
minna (config) #
stats clear-all
Description Clears all statistics.
Syntax stats clear-all
<type> Specifies the following types of alarms: bypass (configures all states for
alarms), cpu_util_indiv, duplex_pri (primary), duplex_aux (auxiliary),
duplex_lan (LAN), duplex_wan (WAN), halt_error, mismatch_peer
(peer mismatch), paging (memory paging), service_error (HP EFS WAN
Accelerator service error), store_corruption (data store corruption),
sw_version (software version mismatch), warning_temp (CPU
temperature).
<options> Specifies the following alarm options:
• clear. Clears alarm settings.
• enable. Enables alarm.
• rate-limit {count [long | medium | short] | [reset] | [window [long |
medium | short]}. Sets alarm event rate-limit values.
• rising. Sets the rising threshold.
• rising clear_threshold <amount>. Sets the threshold to clear rising
alarm. The default value for CPU temperature is 47º C.
• rising error_threshold <amount>. Sets threshold to trigger rising
alarm. The default value for the CPU temperature is 50º C.
• falling clear_threshold <amount>. Sets the threshold to clear falling
alarm. The default value for the CPU temperature is 0º C.
• falling error_threshold <amount>. Sets the threshold to trigger falling
alarm. The default value for the CPU temperature is 0º C.
<CHD ID> Specifies the specific data point: <CHD ID>, cpu_util, cpu_util_indiv,
cpu_util_day, duplex_aux, duplex_lan, duplex_pri, duplex_wan,
memory_day, paging, paging_day, rbt, rbt_day, rbt_month, rbt_week,
rbtkernel, rbtkernel_day, rbtkernel_month, rbtkernel_week.
clear Clears all data.