HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Utilities and Exercisers
71HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Figure 8 shows an example of a FMU translation of a Last Failure Code and an
Instance Code.
Figure 8: FMU translation of a Last Failure Code and an Instance Code
Sample
Controlling the display of significant events and failures
Use the SET command to control how the fault management software displays
significant events and failures.
Table 13 on page 72 describes the various SET commands that can be entered
while running FMU. These commands remain in effect while the current FMU
session remains active, unless the PERMANENT qualifier is entered (the last entry
in the table).
FMU>DESCRIBE LAST_FAILURE_CODE 206C0020
Last Failure Code: 206C0020
Description: Controller was forced to restart in order for new controller
code image to take effect.
Reporting Component: 32.(20)
Description: Command Line interface
Reporting component's event number: 108.(6C)
Restart Type: 2.(02)
Description: Automatic hardware restart
FMU>DESCRIBE INSTANCE 026e0001
Instance Code: 026E0001
Description: The device specified in the Device Locator field has been
reduced from the Mirrorset associated with the logical unit. The nominal
number of members in the mirrorset has been decreased by one. The reduced
device is now available for use.
Reporting Component: 2.(02)
Description: Value Added Services
Reporting component's event number: 110.(6E)
Event Threshold: 1.(01) Classification:
IMMEDIATE. Failure or potential failure of a component critical to proper
controller operation is indicated; immediate attention is required.