HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Troubleshooting Information
56 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Table 11 explains the Error Codes (EC).
SHOW ELEVATION report
The SHOW ELEVATION command retrieves most of the data about a controller
by using one command. The following pages show a sample of the output
generated after a SHOW ELEVATION command is issued.
Table 11: EC Codes
Code Description
0Spin failed on drive.
1 Pub device type does not match NVMEM.
2 Unknown device type.
3 Block size not 512 bytes.
4 Exhausted all command retries.
5 Unsupported capacity (too large).
1
1. Drive capacities greater than 146 GB are not supported by HSG60 and HSG80
array controllers.
6Blank check from drive.
7 Illegal operation code or field in operation code.
8 Vendor unique problem.
9 Drive is not responding to us.
10 Error with the media.
11 Drive is not functioning.
13 Drive tells us it is not ready.
14 Drive failed self diagnotic tests.
15 Error comes from drive hardware.
29 Failure code not yet documented, add new one or see JY.