HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Troubleshooting Information
39HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Last failure reporting
Last Failures are automatically displayed on the maintenance terminal (unless
disabled through the FMU) and use %LFL formatting (see Figure 2).
Figure 2: Sample Last Failure report
nllllmm 3C NVPM write loop hang
occurred.
Attempt to write data to NVPM
failed.
Replace controller.
nllllml 3D NVPM structure revision
is higher than image.
NVPM structure revision number
is higher than the one that can
be handled by the software
version attempting to execute.
Replace program card with one
that contains the latest software
version.
nllllll 3F DAEMON diagnostic
failed hard in
non-fault tolerant
mode.
DAEMON diagnostic detected
critical hardware component
failure; controller can no longer
operate.
Verify that cache module is
present. If the error persists,
replace controller.
Table 6: Solid OCP Pattern Displays and Repair Actions (Sheet 5 of 5)
Pattern
OCP
Code
Error Repair Action
%LFL--HSG> --13-MAY-2004 04:39:45 (time not set)-- Last Failure
Code: 20090010
Power On Time: 0. Years, 14. Days, 19. Hours, 58. Minutes, 42.
Seconds
Controller Model: HSG80
Serial Number: AA12345678 Hardware Version: 0000(00)
Software Version: V088P(FF)
Informational Report
Instance Code: 0102030A
Last Failure Code: 20090010 (No Last Failure Parameters)
Additional information is available in Last Failure Entry: 1.