HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Troubleshooting Information
33HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
nmlmmlm 12 Controller module
memory addressing is
malfunctioning.
Replace controller.
nmlmmll 13 Controller module
memory parity is not
working.
Replace controller.
nmlmlmm 14 Controller module
memory controller timer
has failed.
Replace controller.
nmllmml 15 Controller module
memory controller
interrupt handler has
failed.
Replace controller.
nmllllm 1E During the diagnostic
memory test, the
controller module
memory controller
caused an unexpected
Non-Maskable Interrupt
(NMI).
Replace controller.
nlmmlmm 24 Card code image changed
when the contents were
copied to memory.
Replace controller.
nllmmmm 30 JSRAM battery is bad. Replace controller.
nllmmlm 32 First-half diagnostics
of the Time of Year
Clock failed.
Replace controller.
nllmmll 33 Second-half diagnostics
of the Time of Year
Clock failed.
Replace controller.
nllmlml 35 Processor bus-to-device
bus bridge chip is bad.
Replace controller.
nlllmll 3B An unnecessary
interrupt is pending.
Replace controller.
Table 5: Flashing OCP Pattern Displays and Repair Actions (Continued)
Pattern
OCP
Code
Error Repair Action