HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Troubleshooting Information
29HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Cannot configure
storagesets.
Incorrect command
syntax.
See the controller CLI
reference guide for the
appropriate ADD
command.
Reconfigure storageset
with correct command
syntax.
Exceeded maximum
number of
storagesets.
Use the SHOW
STORAGESETS
command to count the
number of storagesets
configured on the
controller.
Delete unused storagesets.
Failed battery on
ECB. An ECB or
uninterruptible
power supply (UPS)
is required for
RAIDsets and
mirrorsets.
Use the SHOW THIS
command to check the
ECB battery status.
Replace the ECB if
required.
Cannot assign unit
number to
storageset.
Incorrect command
syntax.
See the controller CLI
reference guide for
correct syntax.
Reassign the unit number
with the correct syntax.
Unit is available but
not online.
After created, the
unit automaticaly
comes online.
None. None.
Host cannot see
device.
Broken cables. Check for broken
cables.
Replace broken cables.
Table 4: Troubleshooting Guidelines (Sheet 8 of 9)
Symptom Possible Cause Investigation Remedy