HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
234 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03020101 Invalid SCSI direct-access device OpCode in miscellaneous command
DWD:
Last failure parameter [0] contains the SCSI command OpCode.
01
03040101 Invalid SCSI CDROM device OpCode in miscellaneous command DWD:
Last failure parameter [0] contains the SCSI command OpCode.
01
03060101 Invalid SCSI device type in PUB:
Last failure parameter [0] contains the SCSI device type.
01
03070101 Invalid Command Description Block (CDB) Group Code detected during
create of miscellaneous command DWD:
Last failure parameter [0] contains the SCSI command OpCode.
01
03080101 Invalid SCSI optical memory device OpCode in miscellaneous command
DWD:
Last failure parameter [0] contains the SCSI command OpCode.
01
03090101 Failed request for allocation of PCI miscellaneous block:
Last failure parameter [0] contains the failed DWD command class.
01
030A0100 Error DWD not found in port IN_PROC_Q.01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 21 of 55)
Last
Failure
Code
Description
Repair
Action
Code