HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
212 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Last Failure Code structure
Figure 26 shows the structure of an LFC. By fully understanding this structure,
each code can be translated without using the FMU.
Figure 26: Structure of a Last Failure Code
1 Component ID Code
2 Error Number
3 Repair Action
4 Restart Code and HW flag
5 Parameter Count
0 1 0 0 0 1 0 2
CXO6993A
1
2
4
3
5