HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
206 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
07090064 The failover control received a code load message
from the “other controller” indicating that a new
program image is being written onto the “other
controller” PCMCIA card. During this process,
communication does not occur between the controllers
to keep them operative; however, “this controller”
does not make the “other controller” inoperative.
05 00
0C00370A Memory system error analysis is indicated in the
information preserved during a previous last failure
but no error conditions are indicated in the available
Memory Controller Registers. The quadrant 0 memory
controller (cache A0) registers content is supplied.
14 37
0C103E02 The quadrant 0 memory controller (cache A0)
detected an Address Parity error.
14 3E
0C113E02 The quadrant 1 Memory controller (cache A1)
detected an Address Parity error.
14 3E
0C123E02 The quadrant 2 memory controller (cache B0)
detected an Address Parity error.
14 3E
0C133E02 The quadrant 3 memory controller (cache B1)
detected an Address Parity error.
14 3E
0C203E02 The quadrant 0 memory controller (cache A0)
detected a Data Parity error.
14 3E
0C213E02 The quadrant 1 memory controller (cache A1)
detected a Data Parity error.
14 3E
0C223E02 The quadrant 2 memory controller (cache B0)
detected a Data Parity error.
14 3E
0C233E02 The quadrant 3 memory controller (cache B1)
detected a Data Parity error.
14 3E
0C303F02 The quadrant 0 memory controller (cache A0)
detected a multibit ECC error.
14 3F
0C313F02 The quadrant 1 memory controller (cache A1)
detected a multibit ECC error.
14 3F
Table 53: Instance Codes and Repair Action Codes (Sheet 26 of 30)
Instance
Code
Description Template
Repair
Action
Code