HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
188 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
025F2201
02603A01
Memory diagnostics performed during controller
initialization detected an excessive number of memory
errors (512 pages or more) on the primary cache
memory. Diagnostics have not declared the cache
failed, due to the isolated bad memory regions, but
this is a warning to replace the cache as soon as
possible in case of further degradation. The software
performed the necessary error recovery as
appropriate. In this instance, the Memory Address
and Byte Count fields are undefined.
Applies to mirrored cache memory.
14
14
22
3A
02613801
02623801
02633801
02643801
Memory diagnostics performed during controller
initialization detected that the DIMM in location 1
failed on the cache module. In this instance, the Byte
Count field in undefined.
Applies to location 2.
Applies to location 3.
Applies to location 4.
14 38
02653C01 Memory diagnostics performed during controller
initialization detected that the DIMM in location 3 on
the “other controller’s” cache module (on mirrored
cache) failed. Mirroring is disabled. In this instance,
the Byte Count field is undefined.
14 3C
02663C01 Memory diagnostics performed during controller
initialization detected that the DIMM in location 4 on
the “other controller’s” cache module (on mirrored
cache) failed. Mirroring is disabled. In this instance,
the Byte Count field is undefined.
14 3C
02675201 The device, specified in the Device Locator field, was
removed from the RAIDset associated with the logical
unit. The removed device is now in the failedset. The
RAIDset is now in a reduced state.
51 52
Table 53: Instance Codes and Repair Action Codes (Sheet 8 of 30)
Instance
Code
Description Template
Repair
Action
Code