HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

ASC, ASCQ, Repair Action, and Component Identifier Codes
175HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Component ID Codes
Component ID Codes are embedded in Instance and Last Failure Codes. For a
more detailed description of the relationship between these codes, see the
Instance Codes” chapter that starts on page 177 and the “Last Failure Codes
chapter that starts on page 211.
Table 50 lists the Component ID Codes.
Table 50: Component ID Codes
Code Description
01 Executive services
02 Value-added (VA) services
03 Device services
04 Fault manager
05 Common library routines
06 Dual universal asynchronous receiver and transmitter services
07 Failover control
08 Nonvolatile parameter memory failover control
09 Facility lock manager
0A Integrated logging facility
0B Configuration manager process
0C Memory controller event analyzer
0D Power-off process
OE Peer-to-peer remote copy services
12 VA services (extended)
20 Command Line Interface (CLI)
43 Host port protocol layer
44 Host port transport layer
64 SCSI host value-added services
80
Disk Inline Exercise (DILX)
82
Subsystem Built-In Self-Tests (BIST)
83
Device Configuration (CONFIG)
Utilities
84
Clone Unit Utility (CLONE)