HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

ASC, ASCQ, Repair Action, and Component Identifier Codes
172 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
5C The mirrorset has at least one local Normal or Normalizing member and one remote
Normal or Normalizing member. Failsafe Error mode can now be enabled by entering
the CLI command:
SET unit-number ERROR_MODE=FAILSAFE
5D The last member of the spareset was removed. Add new drives to the spareset.
5E The single member mirrorset has an error in its metadata space which could not be
corrected. Backup data from the mirror and initialize or replace the disk as soon as
possible.
Perform the following steps to remedy this issue:
1. Stop normal write activity to the single member mirrorset.
2. Backup data from the mirrorset with host backup software or equivalent.
Note: Do
not
use the
CLONE
utility.
3. Delete the single member mirror unit, and delete the device.
4. Replace the disk drive with a good disk.
5. Create a single member mirror unit, and then initialize and restore data on the
unit.
69 An unrecoverable fault occurred at the host port. There may be more than one entity
attempting to use the same SCSI ID, or some other bus configuration error, such as
improper termination, may exist. If no host bus configuration problems are found,
follow Repair Action 01.
6A The host connection table has reached its maximum host connections. To add new
connections, you must remove
stale
entries (inactive connections still listed on the
connection table)
from the host connection table, or delete some of the existing host
connections.
80 An EMU fault has occurred.
81 The EMU reported terminator power out of range. Replace the indicated I/O modules.
Table 49: Recommended Repair Action Codes (Sheet 6 of 8)
Code Description