HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Troubleshooting Information
40 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Last Failures are also reported to the host error log on Template 01, following a
restart of the controller. For a detailed explanation of this template, see the “ASC,
ASCQ, Repair Action, and Component Identifier Codes” chapter that starts on
page 161.
Reporting events that allow controller operation to continue
Events that do not cause controller operation to halt are displayed in one of two
ways:
■ Spontaneous Event log
■ CLI Event reporting
Spontaneous Event log
Spontaneous Event logs are automatically displayed on the maintenance terminal
(unless disabled with the FMU) and use %EVL formatting, as illustrated in
Figure 3.
Figure 3: Sample Spontaneous Event logs showing %EVL formatting
%EVL--HSG> --13-OCT-2004 04:32:47 (time not set)-- Instance Code: 0102030A (not yet
reported to host)
Template: 1.(01)
Power On Time: 0. Years, 14. Days, 19. Hours, 58. Minutes, 43. Seconds
Controller Model: HSG80
Serial Number: AA12345678 Hardware Version: 0000(00)
Software Version: V088P(FF)
Informational Report
Instance Code: 0102030A
Last Failure Code: 011C0011
Last failure parameter[0.] 0000003F
%EVL--HSG> --13-OCT-2004 04:32:47 (time not set)-- Instance Code: 82042002 (not yet
reported to host)
Template: 13.(13)
Power On Time: 0. Years, 14. Days, 19. Hours, 58. Minutes, 43. Seconds
Controller Model: HSG80
Serial Number: AA12345678 Hardware Version: 0000(00)
Software Version: V088P(FF)
Header type: 00 Header flags: 00
Test entity number: 0F Test number Demand/Failure: F8 Command: 01
Error Code: 0008 Return Code: 0005 Address of Error: A0000000
Expected Error Data: 44FCFCFC Actual Error Data: FFFF01BB
Extra Status(1): 00000000 Extra Status(2): 00000000 Extra Status(3): 00000000
Instance Code: 82042002
HSG>