HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Troubleshooting Information
37HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
nlmlllm 2E Multiple enclosures
have the same SCSI ID.
More than one enclosure
has the same SCSI ID.
Reconfigure the PVA ID to
uniquely identify each enclosure
in the subsystem. The enclosure
with the controllers must be set to
PVA ID 0; additional enclosures
must use PVA IDs 2 and 3. If the
error continues after PVA settings
are unique, replace each PVA
module one at a time. Check the
enclosure if the problem remains.
nlmllll 2F Memory module has
illegal DIMM
configuration.
Verify that DIMMs are installed
correctly.
nllmmmm 30 An unexpected bugcheck
occurred before
subsystem
initialization
completed.
An unexpected Last Failure
occurred during initialization.
Reinsert controller. If the problem
persists, reset the controller. If the
error persists, try resetting the
controller again, and replace the
controller if no change occurs.
nllmmml 31 ILF$INIT unable to
allocate memory.
Attempt to allocate memory by
ILF$INIT failed.
Replace controller.
nllmmlm 32 Code load program card
write failure.
Attempt to update program card
failed.
Replace program card.
nllmmll 33 Nonvolatile program
memory (NVPM) structure
revision too low.
NVPM structure revision number
is lower than can be handled by
the software version attempting
to be executed.
Verify that the program card
contains the latest software
version. If the error persists,
replace controller.
Table 6: Solid OCP Pattern Displays and Repair Actions (Sheet 3 of 5)
Pattern
OCP
Code
Error Repair Action